        Boiler heating element for Cimbali M20 and M32 3-group espresso machines: 5790 W, 230 V single-phase, 6 poles, 595 mm long, with thermostat bulb sheath. Replace when the machine fails to build pressure, heats slowly or trips the RCD breaker.

        Quantity :
        Write your review
        EU3234363840424446USXX5XSSMLXLXXLXXLArm Length6161,56262,56363,56464,5Bust Circumference8084889296101106111Waist Girth6165697377828792Hip Circumference87919599103108113118
        • Politiche per la sicurezzaPolitiche per la sicurezza(modificale nel modulo Rassicurazioni cliente)
        • Politiche per le spedizioniPolitiche per le spedizioni(modificale nel modulo Rassicurazioni cliente)

        Boiler heating element for Cimbali M20 and M32 3-group professional espresso machines. 5790 W at 230 V, 6-pole connection, complete with thermostat bulb sheath. This is the component that heats the boiler water and maintains the working pressure needed for coffee and steam delivery.

        • Power: 5790 W
        • Voltage: 230 V
        • Phase: single-phase
        • Length: 595 mm
        • Poles: 6
        • Supplied with: thermostat bulb sheath
        • Compatibility: Cimbali M20, Cimbali M32 (3-group versions)

        A failing heating element shows these symptoms: the machine does not build pressure or takes much longer than usual to heat up, the RCD breaker trips at switch-on (compromised element insulation), or the boiler stays cold with the machine powered. Limescale is the main cause of failure: regular boiler descaling extends the life of this part. Replacement requires draining the boiler and should be carried out by a qualified technician.

        Agwsit
        1.001.405
        11 Items

        Specific References

        Agws.it11/14/2020
        Complimenti! Sconto recensione

        Rilascia la tua recensione! per te un buono sconto del 2% comulabile con altre offerte senza limiti di tempo! CODICE RECAGWS

          Write your review
          electric resistance cimbali m20 m32 3gr. 5790w 6poles with sheath
          electric resistance cimbali m20 m32 3gr. 5790w 6poles with sheath

          electric resistance cimbali m20 m32 3gr. 5790w 6poles with sheath

          €39.90
          Tax Included