BLADE SLICER 250E / 40F / 3V / 210i / 17,5h C45blade for slicer 250 diameter 25cm three hole central hole 40mm c45 rgv fac e
  • -10%
PACKAGING OIL FOR SLICERS 100ML
  • -10%
Reviews (1)
€6.59€7.32
PRESSAMERCE HANDLE WITH FLAP
    Reviews (1)
    €7.99
        24v ac coil for parker solenoid valve
        24v ac coil for parker solenoid valve

        24v ac coil for parker solenoid valve

        Reviews (1)
        €19.52
        Tax Included

        24V AC replacement coil for Parker solenoid valves on coffee machines. Solenoid that opens the valve to let water flow to the group. Replaces burnt or shorted coils (valve not switching, humming, no water delivery). Ref. 1.024.062.

        Quantity :
        Write your review
        EU3234363840424446USXX5XSSMLXLXXLXXLArm Length6161,56262,56363,56464,5Bust Circumference8084889296101106111Waist Girth6165697377828792Hip Circumference87919599103108113118
        • Politiche per la sicurezzaPolitiche per la sicurezza(modificale nel modulo Rassicurazioni cliente)
        • Politiche per le spedizioniPolitiche per le spedizioni(modificale nel modulo Rassicurazioni cliente)

        24V AC replacement coil for Parker solenoid valves, used on professional coffee machines. The coil is the solenoid that, when energised by the machine's control board, generates the magnetic field that opens the solenoid valve and lets water flow to the brewing group.

        • Supply voltage: 24V AC (alternating current)
        • Application: Parker solenoid valves for coffee machines
        • Item reference: 1.024.062

        When to replace it: a burnt or shorted coil is one of the most common reasons a solenoid valve stops switching. Typical symptoms are a group that dispenses no water even though the pump runs, a valve that hums without opening, a burnt smell or a visibly blackened coil. The coil can be replaced without opening the water circuit: disconnect the electrical connector, slide the coil off the valve stem and fit the new one, always with the machine unplugged from the mains.

        Before replacing it, it is good practice to check the winding continuity with a multimeter: an open circuit or an out-of-range resistance confirms the fault.

        Agwsit
        1.024.062
        4 Items

        Specific References

        Agws.it11/14/2020
        Complimenti! Sconto recensione

        Rilascia la tua recensione! per te un buono sconto del 2% comulabile con altre offerte senza limiti di tempo! CODICE RECAGWS

          Write your review
          24v ac coil for parker solenoid valve
          24V AC COIL FOR PARKER SOLENOID VALVE

          24v ac coil for parker solenoid valve

          €19.52
          Tax Included